Table 5.6.1: System Notification Report Types (
TT
)
Code Type Code Type Code Type
00 Exterior Instant 11 Zone trouble 22 Zone unbypass
01 Exterior Delay 1 12 Zone trouble rest. 23 Day zone trouble
02 Exterior Delay 2 13 Fuse trouble 24 Day zone trouble restore
03 Interior Instant 14 Fuse trouble restore 25 Up/Download attempt
04 Interior Delay 1 15 Phone line restore 26 Program mode entered
05 Interior Delay 2 16 Disarm 27 Fail to disarm
06 Fire 17 Disarm after activate 28 Fail to arm
07 Panic 18 Arm 29 HWB416 trouble
08 Silent 19 Arm with zones open 2A HWB416 trouble restore
09 Emergency 1A Ctrl low battery 2B Zone open
0A Follower 1B Ctrl battery restore 2C Zone restore (close)
0B Aux type 1 or 2 1C AC Fail 2D Zone Tamper
0C Duress 1D AC restore 2E Zone Tamper Restore
0D Duress not Armed 1E User Communicator test 2F Radio Fail
0E Zone restore after Activ. 1F Auto Communicator test 30 Radio Restore
0F Transmitter low bat 20 Cancel alert
10 Trans. low bat rest. 21 Zone bypass
Example: Zone 14 Open at 10:23 AM on February 21 is 14NQ2B14231021020038.
Keystroke Notification
0BNK
DDD
00
CC
(CR-LF)
Available only in Remote System Mode, which effectively disconnects keypads from the
system and sends keystrokes to a device (a PC or home automation system) programmed to
respond to keypad inputs. Encoded keystrokes are echoed through the RS232 port.
The first character of the 3-character data field indicates the source of the keystroke (K =
System Keypad, L = Local Phone, R = Remote Phone. The second and third characters
encode the keystroke. See Table 5.6.2 for possible values and their meanings.
Table 5.6.2: Keypad Button Codes
Code Key Code Key Code Key Code Key
0x01 1 0x07 7 0x12 Status 0x0C 7-9, 9-F1
0x02 2 0x08 8 0x13 Monitor 0x0E 1-7
0x03 3 0x09 9 0x14 F1 0x11 2-8
0x04 4 0x00 0 0x15 F2 0x0F 3-9
0x05 5 0x0A A 0x0D 1-3, 3-Status
0x06 6 0x0B H 0x10 4-6, 6-Monitor