Control Channel off
0Acf
DD
00
CC
(CR-LF)
Example: turn on Control Channel 1: 0Acf0105(CR-LF)
Control Channel Status Request
08cs0062(CR-LF)
The panel will respond with a Control Channel Status Report for all 56 control channels.
Control Channel Status Report
40CS
D...
00
CC
(CR-LF)
The panel sends this message in response to a Control Channel Status Request.
The data portion of this message is 56 characters long, one character for each control channel
in order. The value will be U (unprogrammed), 0 (Off), 1 (On), or 2-7 (dim-levels 1-6).
Example: With control channel 1 Off, channel 2 On, channel3 unprogrammed, and channel 4
Off, the message would begin 40CS01U0….
5.6. Notification Messages
The panel can be programmed to send notification messages through the RS-232 port when
certain events occur. The two basic categories are System Event Notifications and Keystroke
Notifications.
System Event Notifications
14NQ
DDDDDDDDDDDD
00
CC
(CR-LF)
See the “Communicator Report Options section of your installation manual determine how to
program the panel to send System Event Notification messages through the RS-232 port.
The 12-character data field of this message is divided into six 2-character sub-fields:
•
TT
Event Type 0x00 – 0x30 (see Table 5.6.1)
•
ZZ
Zone or User Number 00 – 95 (0 –referenced: Zone or User1 is 00)
•
MM
Minutes 00 - 59
•
HH
Hours 00 – 23
•
DD
Day 01 - 31
•
XX
Month 01 - 12
System Notification Messages are reported in real time. Data in the
TT
position will be one
of the reports in Table 5.6.1. Reports of type 00 through 0D are activations that cause the
system to generate an alarm. If the zone is an input with an open and close state (keypad
activations do not), the Activation Event report will be preceded by an Open or Close report.
A bypassed zone will still send Open and Close reports.
9