Programming
System options are contained in EEPROM. Each programmable section of memory has a 4 digit location and a
three digit value. To reduce the amount of programming necessary, each location is supplied with a default
value. The programming process can be simplified and the chances of programming errors can be reduced by
obtaining a copy of the Windows 95 based PC software available from apex, the BBS at 919-954-0318 or our
web site at www.ademco.com/apex. The BBS settings are no parity, 8 bits with 1 stop bit, and connection
speeds up to 28.8 baud.
Program Mode
To program new values into memory locations, it is necessary to first place the system into program mode.
This is achieved in the same manner from a keypad or remote telephone; from keypad mode (anytime the
system is in an idle state) enter the service code (factory default of 9,1,7,3). The system will respond with
ENTER PROGRAM MODE. The LED's on keypads will turn off.
Locations and Values
Programming requires the entry of a valid 4 digit program location followed by the entry of a 3 digit
programming value. When a valid program location is entered, the inside speaker will emit one beep. Press
the H (# from telephone), the system will speak the current value in the location. To establish a new value,
reenter the 4 digit location and type the desired new value after the single confirmation beep. The system will
confirm the new program value by speaking the location followed by the value. To cancel a current program
location at any time prior to the system speaking the programming confirmation, press A (* from telephone), at
that point a new location can be entered. If the system responds with three beeps after a location is entered, an
invalid location has been entered. Values entered into undocumented locations may cause spurious system
operation.
Exiting Program Mode
To exit program mode, enter 9,8,9,9, instead of a program location, the system will respond with EXIT
PROGRAM MODE." If a key (or digit) is not pressed within the time period programmed in location 0557, the
system will automatically exit program mode.