Required Programming
Application Diagram
Sunrise / Sunset Lighting
Sure Action Photo Cell, 12 volt
Location Value Function
4865 009 Enable control channel 33 with automatic turn-off
4867 128 Turn channel on when dark(sunset)
4869 120 On units(minutes)
4886 096 X-10 output signal = A1
4889 001 Enable control channel 34
4892 008 Disable channel when light(sunrise)
4910 097 X-10 output signal = A2
0189 034 Pre-alarm trigger channel
4059 002 Pre-alarm trigger option(activation = on, restore = none)
9940 01 Zone type = 001, Option 1 = 080, Option 2 = 001,
Hardware device = 000, Input = 01
9940 16 Zone type = 016, Option 1 = 000, Option 2 = 001,
Hardware device = 000, Input = 16
9920 001 077(Front), 060(Door)