Destiny apex 6100 Manual de usuario Pagina 70

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 77
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 69
Sequence of Operation
System Sequence of Events
Objective Equipment List
¨ Apex Destiny 6100 control panel,
rev. 8.05 or greater
¨ System Sensor Relay, A77-716B
- Arm to Away End of Exit Trigger -
This application can be used to provide an audible and / or visual
indication when the exit delay has expired and the control is armed.
After arming to Away, the exit countdown will begin. When the exit delay expires a relay output
will be given. The relay output will restore when the control is disarmed.
Provide an output relay that will
activate at the end of the arm to
Away exit delay.
1) Arming to Away activates Control Channel 3 which triggers Chain Group 1 to first energize
the on-board relay (Auxiliary Output 8) and then Auxiliary Output 1. The ground signal from
Auxiliary Output 1 is now available at the normally closed (NC) contacts of the on-board relay.
2) This signal will pass through to Zone 1 when the on-board relay is returned to its normally
closed position after the turn-off delay period (programmed same as the exit delay time).
3) Zone 1 is linked to Control Channel 5 so when it is tripped Auxiliary Output 2 will pull to
ground and energize the output relay.
4) When the system is disarmed Control Channel 4 will trigger Chain Group 2 to first
deenergize Auxiliary Output 1 and then the on-board relay. This will deenergize the output
relay returning it to its normal state.
Apex Technical Support 800-272-7937