Required Programming
Application Diagram
Annunciated
Vehicle Detection
with Lighted Entry
Sure Action Directional Probe
07/99
Location Value Function
9940 01 Zone type = 011, Option 1 = 064, Option 2 = 001,
Hardware device = 000, Input = 01
9940 02 Zone type = 011, Option 1 = 064, Option 2 = 001,
Hardware device = 000, Input = 02
9940 03 Zone type = 016, Option 1 = 000, Option 2 = 001,
Hardware device = 000, Input = 03
4097 013 Enable channel one, countdown in minutes, restart timer and auto turn off
4100 200 Disable channel one when disarmed, armed to Away, and sunrise
4101 003 Set ON time for 3 minutes
4118 096 Set house code and unit number to A-1
0901 001 Set option for zone 1 open to send an ON command
0902 001 Link zone 1 to control channel 1
0917 001 Set option for zone 2 open to send an ON command
0918 001 Link zone 2 to control channel 1