Required Programming
Application Diagram
Bathroom Courtesy Fan
Location Value Function
9940 01 Zone type = 011, Option 1 = 000, Option 2 = 001,
Hardware input = 000, Input = 1
4886 096 Assign Control Channel 33 to the X-10 unit A1
4865 009 Enable Control Channel 33 with countdown in minutes
4869 015 Assign a 15 minute countdown
0902 033 Link Zone 1 to Control Channel 33
0901 001 When Zone 1 opens, send an "ON" command to channel 33
Note: Follow the Pulsor’s enclosed instructions for installation
and sensitivity adjustment.