Sequence of Operation
System Sequence of Events
Objective Equipment List
Apex Technical Support 800-272-7937
Option 1
Page 4-3
¨ Apex Destiny 6100 control panel,
rev. 8.05 or greater
¨ Apex RK36 or RKLCD keypad
¨ System Sensor Relay, A77-716B
- Doorbell Chime with Greeting Message -
When the doorbell is
pressed, it will give its
normal chime followed by
a greeting message.
When someone presses the doorbell the normal doorbell chime will sound followed by a
greeting message over the internal speakers and/or keypad speakers.
1) Zone 1 (door bell) activates sending an ON command to activate Control Channel 1 (Chain
Channel 1) which energizes Auxiliary Output 2 which in turn energizes the door bell chime
relay. The relay will turn off after one second.
2) Channel 1 also energizes the on-board relay (Auxiliary Output 8) and then Auxiliary Output 1.
The ground signal from Auxiliary Output 1 is now available at the normally closed (NC) con-
tacts of the on-board relay. This signal will pass through to Zone 2 (Guest At Door) when the
on-board relay is returned to its normally closed position after two seconds and the system will
speak Guest at Door.
This application can be used when there are multiple doorbells (front
door, side door, back door) and the end user would like to know exactly
which doorbell was pressed.
- Application Note -
End User Convenience
Vista de pagina 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 76 77

Comentarios a estos manuales

Sin comentarios