Required Programming
Application Diagram
Doorbell Interface with Local Two-Way Voice
Location Value Function
9940 01 Zone type = 011, Option 1 = 064, Option 2 = 033,
Hardware device = 000, Input = 01
9920 001 083(Guest), 306(At), 077(Front), 060(Door)
4097 001 Enable control channel 1
4119 008 Assign control channel 1 to the on-board relay
0203 001 Activate the on-board relay only while 2-way voice is active