Required Programming
Application Diagram
Delayed HVAC Cut-Off After Door Opening
Location Value Function
9940 01 Zone type = 001, Option 1 = 080, Option 2 = 001,
Hardware device = 000, Input = 01
9940 02 Zone type = 011, Option 1 = 000, Option 2 = 001,
Hardware device = 000, Input = 02
9940 03 Zone type = 013, Option 1 = 064, Option 2 = 001,
Hardware device = 000, Input = 03
4097 001 Enable control channel 1
4119 009 Auxiliary output 9
4121 001 Enable control channel 2
4143 010 Auxiliary output 10
4145 001 Enable control channel 3
4167 011 Auxiliary output 11
0901 009 Zone - Control Channel Link Option (open = ON, close = OFF)
0902 001 Zone - Control Channel Link Option (Zone 1, Channel 1)
0917 009 Zone - Control Channel Link Option (open = ON, close = OFF)
0918 002 Zone - Control Channel Link Option (Zone 2, Channel 2)
0933 009 Zone - Control Channel Link Option (open = ON, close = OFF)
0934 003 Zone - Control Channel Link Option (Zone 3, Channel 3)
07/99