Required Programming
Application Diagram
Sequenced Sprinkler Control
Location Value Function
4097 009 Enable control channel 1 and enable automatic turn-off in minutes
4101 015 On units
4119 009 Auxiliary output 9
4121 009 Enable control channel 2 and enable automatic turn-off in minutes
4125 030 On units
4143 010 Auxiliary output 10
4145 009 Enable control channel 3 and enable automatic turn-off in minutes
4149 045 On units
4167 011 Auxiliary output 11
4169 009 Enable control channel 4 and enable automatic turn-off in minutes
4173 060 On units
4191 012 Auxiliary output 12
4193 001 Enable control channel 5
4195 001 Enable chain channel
4214 001 Channel group assignment 1
5441 001 Channel activation 1
5442 002 Channel activation 2
5443 003 Channel activation 3
5444 004 Channel activation 4
4021 005 Output control assignment 1
4022 002 Toggle control channel on / off
3630 024 Keypad F1 button linked to output control assignment 1