Application Diagram
Required Programming
Silence a Selected Keypad / Internal Speaker
in Home / Night Modes
07/99
Location Value Function
4097 001 Enable control channel 1
4119 008 On-board relay
4121 011 Enable control channel 2 for Auto Turn OFF
4125 005 Sets Turn OFF time for five seconds
4143 008 On-board relay
0193 001 Links Arm to Home trigger to channel 1
4063 002 Arm to Home activation action = ON, restore action = NONE
0209 001 Links Arm to Night trigger to channel 1
4079 002 Arm to Night activation action = ON, restore action = NONE
0196 002 Links Disarm trigger to channel 2
4066 002 Disarm activation action = ON, restore action = NONE
0183 001 Links Any Alarm Activation trigger to channel 1
4053 001 Any Alarm trigger activation action = OFF, restore action = NONE